On this page you find the APC Power-Saving Back-UPS Pro 900 manual. Please read the instructions in this operator manual carefully before using the product. If you have any questions about your that are not answered in the manual, please share your question in the. RefurbUPS is the nation's most trusted source today for Performance Guaranteed power protection solutions. We supply more than 10,000 customers nationwide including today's leading corporations, retailers, government, and educational institutions.
- Apc 900va Back Ups
- Apc Back-ups Rs 900 Manual
- Apc Back Ups 500 Battery
- Apc Back Ups Xs 900 Manual
- Apc Back-ups Xs 900 User Manual
®
Caution
• For safety, the Back-UPS ES is shippedwith one battery wire disconnected. Small sparks may occur during battery
• Do not install the unit in direct sunlight, in excessive heat or humidity, or in contact with fluids.
•Connectthepower cord directlytoa wall outlet; not a surge protector or power strip. The outlet
must be located near the equipment and easily accessible.
Apc 900va Back Ups
Overview
Press the ON/OFF switch to turn the unit ON. A single short beep and the green “Power On” indicator confirms that
Back-UPS ES is on and ready to provide protection. The UPS will automatically perform a self-test when power is
applied tothe unit, the green LED will flash during the self-test.
Note: Prior to first use, charge the Back-UPS for at least 16 hours to ensure sufficient runtime. The unit is charging
whenever it is connectedto utility power, whether the unit is turned ON or OFF.
Master Outlet--Connect a master device, such as a computer. See
2
Apc Back-ups Rs 900 Manual
Battery Backup and Surge Protection--These outlets receive
power whenever the unit is ON. During a power outage or other
utility problems (brownouts, over-voltages), these outlets will
receivepower from the unit for a limited time. Connect a computer,
monitor, and two other data-sensitive devicesinto these outlets.
Note that one of these outlets is the Master outlet. See “Using the
3
Controlled Outlets--Connect peripheral devices. See “Using the
4
Surge Protection--These outlets provide full-time protection from
surges even if the unit is OFF, but will only supply power when the
unit is ON. Connect a printer, fax machine, scanner, or other
peripherals that donot need battery power during power outages.
Note that if the power-saving feature is enabled, three of these
5
Data Port--Use the supplied RJ45/USB cable to connect the Back-
UPS unit to a computer to install the software. See “Install the
6
Circuit Breaker—Push to re-set the circuit breaker.
Modem/Phone/Fax—Connect a DSL or dial-up modem, phone,
fax machine, or 10/100 Base-T ethernet equipment. Note: Donot
Apc Back Ups 500 Battery
connect the UPS telephone protection ports to both the
Apc Back Ups Xs 900 Manual
telephone and network system cables at the same time.
Apc Back-ups Xs 900 User Manual
Wall outlet—Connect the unit to a data line wall outlet.